Description
The ECM888B is a 1/4" standard measurement microphone with internal
battery. No external power needed for easier connection to various
devices. Such as real time analyzer, PC based measurements, or palm
size devices. Wide and flat frequency response makes this ECM888B an
ideal measurement and recording microphone.
Features
Cautions
! Wide frequency response from 20Hz to 20KHz.
! 1/4" industrial standard dimension.
! Omni directional.
! Internal battery, 4LV44, 6V battery
.
! All metal structure, durable and long lasting live time.
1. When the microphone is connected, do not un-screw the microphone
that may cause impact signal to the connected system.
2. Turn off the level on the audio system before disconnecting the
microphone.
3. Battery life time is 300 hours. If the signal is low or no signal,
replace the battery.
4. Before replace the battery, disconnect the microphone from the
system.
5. Insert the battery according to the illustrated polarity on the bo
dy.
Anode shall point toward the XLR3M plug. Cathode shall point to the
capsule tip. If the battery is not properly inserted, the microphone
will not be damaged, but will not work either.
6. To save the battery power, remove the battery when the microphone
will not be used for a long period.
7. Place foam wind screen when in outdoor to reduce wind noise.
1
Specifications
ECM 888B
User Guide
1/4" Measurement Microphone
G O A N G - F A N N C O . , L T D .
© 2007, SUPERLUX I
LB100888B01EN (Rev. 1)
nc.
Back electret condenser
Type
Pressure, FET preamplifier.
Element
Polar pattern
20 to 20,000 Hz (Figure 2)
Frequency response
Sensitivity
(at 1,000 Hz Open Circuit Voltage)
-43dBV/Pa (7.1mV/Pa)
1Pa=94dB SPL
± 3dB
800Ω
Rated impedance
3,000Ω
Minimum load impedance
Equivalent noise level
(A-weighted)
22dB
Omnidirectional (Figure 1)
Max. SPL (1 kΩ load)
128dB SPL (THD1% 1kHz)
106dB
Dynamic range (1 kΩ Load)
The ECM888B operates b
etween
-10 to +50(14 to 122)
with relative humidity between 0
to 95%.
Environmental conditions
Pin 2 output positive voltage
(related to pin 3) when diaphragm
receives positive pressure.
(Diaphragm moving inward)
Polarity
3 pin male XLR type
Connector
Finish
Dimensions
Weight
150g (5.30 oz.), Battery excluded
0.5mA, >300 hour
Current consumption
72 dB
Signal-to-noise ratio
Φ21.0x170.0mm (0.83x6.70 in.)
Figure 3
Power supply
4LR44 6V battery
Metal construction wi
th
champagne painted finish
The ECM888B, including the
product and packages follow the
instruction of EU 2002/95/EC and
comply to RoHS.
RoHS
2

TYPIC AL POLAR PATTERN (Figure 1)
80 00 Hz
16 000 Hz
10 00 H z
20 00 H z
40 00 H z
TY PICAL FR EQUENCY RESPONSE
(Fi gure2 )



dB
10
-1 0
-2 0
20 50 10 0 20 0 50 0 10 00 2000 50 00 1 0000 20 000 Hz
0
Vue de la page 0
1 2

Résumé du contenu

Page 1 - User Guide

-3-DescriptionThe ECM888B is a 1/4" standard measurement microphone with internal battery. No external power needed for easier connection

Page 2 - About Frequency Response

-4--5--6-Extremely light weight diaphragm, very sensitive to sound. Very small versions available for hiding applications. High perform

Commentaires sur ces manuels

Pas de commentaire